pH and Electrochemistry
Instruments and other methods to measure pH, conductivity, specific ions, dissolved oxygen, and other parameters; may be handheld or benchtop and manual or electronic (analog or digital); includes pH indicator papers, electrodes, and other probes.
pH and electrochemistry meters and related products are used to assess acidity and alkalinity, conductivity, specific ion concentrations, and dissolved oxygen in water, wastewater, and other solutions. Electrochemistry meters may measure a single parameter (like pH) or they may be multiparameter meters, capable of performing a combination of tests (pH plus conductivity, for example).
Electrochemistry meters are used with various probes and electrodes designed for specific purposes or types of solutions. Electrodes with epoxy bodies are useful for testing food, beverages, and other materials where broken glass could be a problem. Other electrodes are made to withstand higher than usual impact; for use with solutions that contain large particulates; and for compatibility with biological buffers.
Electrodes must be carefully stored and maintained for optimal performance. It’s important to select the right storage bottles and electrode filling, cleaning, rinsing, and storage accessories.
Electrochemistry meters also require regular calibration and maintenance. Standard and certified pH buffers as well as conductivity and specific ion standards are available. Other accessories include electrode supports, bulb guards, cables, connectors, and adapters.
Indicator paper and test strips are another simple, portable, and qualitative way to quickly determine pH and other analytes. The paper or strips contain chemical indicators that produce color reactions. A comparison chart (included) helps to interpret the results. Available in various pH ranges, these are sometimes called “litmus” paper.
Filtered Search Results
METTLER TOLEDO™ InLab™ Conductivity Benchtop Probes
A selection of conductivity probes suitable for all applications.
| Sensor Types | Integrated Temperature Sensor |
|---|---|
| For Use With (Application) | General conductivity measurements |
| Connector Types | Mini-DIN |
Thermo Scientific™ Orion Star™ A321 pH Portable Meter
Accurately monitor pH, mV, ORP and temperature with our waterproof, portable pH meter for high performance in challenging field locations.
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
|---|---|
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Measurement Modes | pH,mV,Relative mV,ORP with Temperature |
| Range (pH) | -2 to 20 |
| Channels | 1 |
| Accuracy (pH) | ±0.002 |
| Power Supply | 4 AA batteries (included) or universal AC adapter (sold separately) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Battery Life | 800 hr. |
| Display Type | LCD Graphic, Backlit |
| Resolution (mV) | 0.1mV |
| Data Points | 5000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe) |
| Weight (Metric) | 0.5 kg |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 Year Meter |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Isopotential Point | 7.000pH |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003) |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP and temperature |
| Battery Type | 4 x AA |
| Relative Humidity Range | 5 to 85%, non-condensing |
| Calibration Points | 1 to 5 |
| Alarm Output | High/low limit alarm, calibration due alarm |
| Dimensions (L x W x H) | 24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| IP Rating | IP67 |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Model | Orion Star A321 pH/mV/RmV/ORP/Temperature Portable Meter |
| Outputs | USB, RS-232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Backlight Option | Yes (Selectable) |
| Weight (English) | 1.2 lb. |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel with password protection |
| Temperature Resolution | 0.1°C, 0.1°F |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/Conductivity Multiparameter Benchtop Meter
Get premium performance and flexibility with our benchtop meter with pH and conductivity modules for simultaneous pH, conductivity, and temperature.
| Power Rating | DC input: 9VDC, 1A |
|---|---|
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
| Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Resolution (pH) | 0.1/0.01/0.001 |
| Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
| Measurement Modes | pH,mV,Relative mV,TDS,ORP with Temperature,Salinity,Conductivity,Resistivity with Temperature |
| Power Supply | Universal AC adapter (included) |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Color graphic LCD with user-customizable options |
| Resolution (mV) | 0.1mV |
| Data Points | 2000 with Date and Time Stamp |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Warranty | 3 year meter and module warranty |
| Temperature Accuracy | ±0.1°C |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
| Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Dimensions (L x W x H) | 28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Temperature Selection | Manual or automatic with ATC temperature probe |
| Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB (2), RS232 |
| Temperature Range (English) | 22.0°F to 221.0° F |
| Range (Relative mV) | ±2000.0 mV |
| Calibration Points (pH) | 1 to 6 |
| Backlight Option | Yes |
| Range (mV) | ±2000.0 mV |
| Range (ORP) | ±2000.0 mV |
| Methods | 10 per channel |
| Cell Constant | 0.001 to 199.9cm-1 |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Range (pH) | -2 to 20 |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Channels | 4 (Customizable with modules) |
| Accuracy (pH) | ±0.002 |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe) |
| Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
| Calibration Points (Conductivity) | Up to 6 |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Isopotential Point | 7.000pH (adjustable) |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
| Range (TDS) | 0.001 ppm to 200.0 ppt |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Calibration | pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Weight (English) | 2.5 lb., modules add 0.5 lb. each |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Temperature Range (Metric) | -5.0°C to +105.0°C |
| Temperature Resolution | 0.1°C, 0.1°F |
Mettler Toledo™ SevenGo™ perfectION Combined ISE Electrodes
Get an All-In-One Solution with SevenGo™ perfectION Combined ISE Electrodes. The brilliant Click & Clear™ press mechanism allows for quick cleaning and ensures stable readings even in difficult samples.
| Type | Combination ISE |
|---|---|
| Electrode | Combined ISE Electrode |
| For Use With (Equipment) | All pH, mV Meters or Ionometers |
| Material | Epoxy |
| Filling Solution Type | ISA |
| Connector Types | Lemo |
Thermo Scientific™ Orion™ Pro Star EC212 Conductivity Bench Meter with Stand
Designed to provide accurate and reliable conductivity, TDS, salinity, resistivity and temperature analysis, the Thermo Scientific™ Orion™ Pro Star EC212 bench meter is well suited for laboratories that desire a modern meter with advance performance.
| Salinity Measurement Modes | Natural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl |
|---|---|
| Range (Resistivity) | 1.0 Ω to 100.0 MΩ |
| Memory | Non-volatile |
| Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese, Spanish |
| Cell Constant | 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1 |
| Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature,Resistivity with Temperature |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25 or 30°C |
| Channels | 1 |
| TDS Factor Range | Linear (0.01 to 10.00), ISO/EN 27888, 442, NaCl |
| Range (Salinity) | 0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl |
| Temperature Compensation | Linear (0.00 to 10.00 %/°C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP/USP or off |
| Display Type | 7-in. High-resolution Color Graphic LCD |
| Accuracy (Salinity) | ±0.5% reading |
| Resolution (Salinity) | 0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging |
| Accuracy (Conductivity) | ±0.5% reading |
| Data Points | 10,000 with Date and Time Stamp |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 or 2 point temperature offset calibration |
| Inputs | 8-pin MiniDIN for conductivity with ATC |
| Accuracy (Temperature) | ±0.3°C, ±0.5 °F |
| Weight (Metric) | 1 kg |
| Calibration Points (Conductivity) | 1 to 5 points |
| Warranty | 2 year meter warranty |
| Resolution (Resistivity) | 0.1 Ω minimum, auto-ranging |
| Resolution (Conductivity) | 0.001 μS/cm minimum, auto-ranging, up to 4 digits |
| Range (Conductivity) | 0.010 μS/cm to 3000 mS/cm |
| Accuracy (Resistivity) | ±0.5% reading |
| AC Adapter | Universal 100-240 V 50/60 Hz power supply with wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
| Log Function Type | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
| Range (TDS) | 0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg/L to 500.0 g/L (TDS factor of 1.00) |
| Resolution (TDS) | 0.001 ppm or mg/L minimum, auto-ranging, up to 4 digits |
| Calibration | Conductivity, TDS, Salinity, Temperature |
| Calibration Points | 1 to 5 (conductivity), 1 to 5 (TDS), 1 (salinity), 1 to 2 (temperature) |
| Alarm Output | Calibration reminder alarm, high and low limit alarm per parameter |
| Dimensions (L x W x H) | 218.9 x 153.2 x 91.33 mm; 8.62 x 6.03 x 3.60 in. |
| Accuracy (TDS) | ±0.5% reading |
| IP Rating | IP54 |
| Temperature Selection | Automatic with ATC temperature sensor, ambient or manual |
| Keypad | Capacitive touchscreen user interface |
| Model | EC212 |
| Outputs | USB flash drive, computer or printer (STARA-106) |
| Backlight Option | Yes |
| Temperature Range (English) | -22°F to +266°F |
| Weight (English) | 2.20 lbs. |
| Resolution (Temperature) | 0.1°C, 0.1°F |
| Temperature Range (Metric) | -30°C to +130°C |
| Methods | 10 |
Thermo Scientific™ Orion™ DuraProbe™ Epoxy Bodied Graphite 4-Cell Conductivity Electrodes
Measure the most challenging samples accurately and under a wide range of conditions with these conductivity electrodes.
| Min. Immersion | 35 mm |
|---|---|
| Sensor Types | 4 Electrode Graphite Cell |
| Storage Method | Store in distilled or deionized water between measurements; for overnight or long-term storage, thoroughly rinse and store dry |
Thermo Scientific™ Orion™ Epoxy Bodied Temperature Probes
Get fast, accurate measurements in lab or field with this ATC Probe, which automatically corrects pH measurements for variation in electrode slope.
| Diameter (English) Body | 0.2 in. |
|---|---|
| Type | ATC Probe |
| Accuracy | ±1°C |
| Length (Metric) | 120 mm |
| Temperature (English) Operating | 32°F to 176°F |
| pH Range | 0 to 14 |
| Length (English) | 4.7 in. |
| Material | Epoxy |
| Diameter (Metric) Body | 6 mm |
| Temperature (Metric) Operating | 0°C to 80°C |
OHAUS™ Starter Water Analysis Meter Replacement Electrodes
Replacement electrodes for Starter portable and benchtop meters.
| Diameter (English) Body | 0.47 in. |
|---|---|
| Length (Metric) Cable | 1 m |
| For Use With (Equipment) | Starter 300 pH meter |
| Sensor Types | pH Electrode |
| Length (English) Cable | 39.3 in. |
| Filling Solution Type | 3 mol/L KCl gel |
| Measurement Ranges | pH 0 to 14 |
| Cell Constant | 0.1 μS/cm |
| Diameter (Metric) Body | 12 mm |
| Internal Reference | Ag/AgCl |
Mettler Toledo™ FiveEasy™ F20 pH/mV Meters
Compact, benchtop meter provides high quality pH/mV measurements with simple click of a button
| Accuracy (mV) | ±1 |
|---|---|
| Memory | Current calibration |
| Resolution (pH) | 0.01 |
| Range (pH) | 0 to 14 |
| Calibration | Linear |
| Accuracy (pH) | ±0.01 |
| Temperature Compensation | ATC and MTC |
| Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
| Display Type | LCD |
| Voltage | 120/240 V |
| Model | F20 |
| Resolution (mV) | 1mV |
| Frequency | 50/60 Hz |
| Temperature Range (English) | 32°F to 212°F |
| Weight (English) | 1.4 lb. |
| Resolution (Temperature) | 0.1°C |
| Temperature Range (Metric) | 0°C to 100°C |
| Range (mV) | 2000 to 2000 |
| Inputs | BNC, Cinch, NTC 30kiloOhm sensors |
| Accuracy (Temperature) | 0.5°C |
| Weight (Metric) | 0.63 kg |
METTLER TOLEDO™ InLab™ Versatile pH Electrode
A plastic, refillable pH electrode with an integrated temperature sensor ideal for measuring liquids. Electrode features a replaceable ceramic junction, which offers a solution to contaminated junctions without the higher cost or cleaning efforts required with open or sleeve junctions.
Mettler Toledo™ Replacement Parts for C20 Karl Fischer™ Autotitrator
Accessories For use with Mettler Toledo C20 Karl Fischer™ Autotitrator
Mettler Toledo™ V20 Karl Fischer™ Titrator 10mL Interchangeable Buret
Interchangeable Buret for use with V20 Karl Fischer Titrator.
Mettler Toledo™ DL31 Karl Fischer™ Titrator Replacement Parts: Electrodes
Replacement parts for DL31 Karl Fischer titrators.
Mettler Toledo™ perfectION™ Gas-Sensing Combination Electrodes
Allows quick and easy determination of concentration and activity of dissolved gases. Mettler Toledo perfectION Gas-Sensing Combination Electrodes are resistant to any known organic chemical present whose temperature is less than 392°F (200°C).
METTLER TOLEDO™ InLab™ 413/IP67 pH Electrode
A durable, plastic body pH electrode ideal for a wide range of applications that is able to withstand wet and demanding environments (IP67 rated).